Life on the road as a noise assessor

Noise assessments around the UK: A noise assessor’s diary

Where I am working, the type of industry and any interesting issues which arise.

As always, the terminology used is aimed at normal people rather than noise or safety specialists, hence using ‘limits’ to refer to Exposure Action Values, or ‘volume’ in place of ‘sound pressure level’, etc.

Bridgend, South Wales: Product assembly

18th November 2026

A site in Bridgend asked for a noise assessment to be done. They had received a noise assessment from another provider recently but they were unhappy with it and I was recommended to them by another company in the area for whom I had done a noise assessment earlier this year.

An interesting issue here is one which does come up from time to time and is one which, quite understandably, employer can miss as it gets deep into the weeds on hearing protection.

The ear muffs in use were stamped as certified to EN 352: 1993. EN 352 is the standard for hearing protection but it was revised in 2002 and again in 2020. There is a grace period between each revision but the stamp of 1993 does mean that these muffs must be at least 21 years old now, while the life expectancy for this type of muff is typically up to three years.

Hearing protection does not last forever and does expire, something which is easy to overlook.

Another issue present is one which a lot of employers need to watch out for - dropping pallets into place. Average noise levels were low, around 77 dB(A), but there were instances of peak noise at 139 dB(C) caused by pallets being dropped. That can mean hearing protection is now mandatory despite the low overall noise levels. It is easy to address though - thin rubber mats where the pallets are loaded will dampen the noise and control the risk.

Black Country, West Midlands: Plastics extrusion

16th November 2026

A small plastics extruder in the Black Country, near Birmingham, received a visit from the HSE and needed to get a noise assessment done.

I’ve just been to the site and it is one of the rarer jobs where the noise assessment largely confirms an absence of noise risk for them as average noise levels over a day will be around 83 dB(A). They can now go back to the HSE confirming that their optional hearing protection policy is correct.

There was one interesting element - the use of air jets to dry plastics off before winding. There were two types of nozzle being used, with several extrusion lines using narrow nozzles and one line using wider ones.

It makes a significant difference to the noise, with the narrow ones being around 97 dB(A) and the wider one 93 dB(A), both connected to the same air supply.

The wider one is still over the 85 dB(A) legal limit but that difference of 4 dB(A) means it is actually more than twice as safe as the louder, narrower, nozzles. A nice easy-win for the site as simply changing the remaining narrower plastic heads on the end of the air jets will more than halve the noise risk.

Near High Wycombe, Buckinghamshire: Pipe and tube manufacture

11th November 2026

A site producing ductwork asked for a noise assessment for their factory near High Wycombe. Noise was as you would expect for this type of operation, going up to around a daily average of 94 dB(A) for the louder jobs where pipes are created and then cut into lengths.

One issue here was one which a lot of employers may find is also the case, in that the hearing protection in use had expired, meaning gone beyond its usable shelf life. All hearing protection expires and companies need to be careful to only buy in what is needed rather than keeping large stocks in just in case.

Spalding, Lincolnshire: Food industry

10th November 2026

This company was a prepared food provider and as they get busier they have been adding new lines and new chilled good areas. Two issues which came up in this noise assessment which are of interest to employers generally were:

  • Adding new lines made a significant change to the noise level for some personnel. Previously all personnel were below the main 85 dB(A) action value but the new line had pushed one area up to the 87 dB(A) point. This is commonly the case where production areas become more tightly packed.

  • A chiller area was interesting in that in normal use the noise was OK, at around 83 dB(A), however when the fans are ramped up in hot weather noise quickly crosses the 85 dB(A) threshold. Fan noise is well-known for this where a small increase in speed can create a disproportionate increase in noise level. That’s worth bearing in mind when measuring noise levels, especially in colder months - what is acceptable now could become an issue in warmer periods.

South of England: Packaging industry

5th November 2026

You will have to forgive me for being vague on the location here but that is deliberate. I did a noise assessment for a packaging factory where noise in two areas was around the 87 to 88 dB(A) level. Hearing protection usage by people working there was poor but the stand-out issue was that the manager overseeing the production area, and spending all their time in and around the noise, never used hearing protection.

Managers ‘walking the walk’ is vital in noise safety - staff compliance with hearing protection can be hard at the best of times and if a manager is continually spending time in a high noise area without ever wearing hearing protection, the job of getting compliance is going to be extremely hard. This was a great example where the focus on the need for hearing protection needs to start with one key individual and then spread outwards from there.